CACHE
TURBOCHARGING
DATA SHEET (North America)
Dish/Roof Requirements |
Dish type |
1.2 meter non-penetrating roof mount
receive terminal for most areas. |
Dish size |
1.2 meter standard mount in most areas.
Remote or humid locations may require larger dishes. |
Dish footprint |
52.5" x 52.5" for 1.2 meter
mount.
Footprint Map |
Dish & mount weight |
70 lbs. for mount & antenna system,
plus 12-30 concrete blocks weighing approximately 33 lbs. per block. |
Roof loading |
Distributed load of 24.3 lbs./sq. ft to
55.4 lbs./sq. ft. |
Rack Requirements |
Both satellite receiver and cache adapter
are mountable in 19-inch cabinet or rack. Shelves are required for both units. |
|
Receiver |
Cache Adapter |
Physical dimensions
Rack space |
2.75" tall x 12.25"x 9.25" |
3.25" tall x 16.25" x 16.25" |
Weight |
5 lbs. |
20 lbs. |
Operational environment:
|
Temperature
Humidity range |
32 F/
104 F |
32 F/
104 F |
Non-operational Temperature Humidity range
|
32 F/
104 F |
32F/
104 F |
Power Requirements |
120/240 VAC |
110-240 VAC; 47.63 Hz, .4 kVa |
DC power for receiver and Cache Adapter an
option.
|
Environmental Requirements |
UPS conditioned power preferred for both
Receiver and Cache Adapter. |
Network Requirements
|
Pre-installation |
One IP address
Reverse DNS mapping
Default gateway
Net mask
DNS |
Physical |
10Base T Ethernet into network hub. |
Bandwidth |
Dedicated connection to the Internet of 56K
or better. |
Cache/Cache Peering |
Must recognize SkyCache Cache Adapter as an
ICP sibling.
A cache/cache cluster with a minimum of 12-16GB of disk is recommended. |
Usenet
News |
NNTP compatible server. |
Data throughput |
Maximum: 4 Mbps/second |
Installation |
Legal/Regulatory |
Roof rights/roof access for dish install by
contractor. |
Estimated time |
Approximately 5-10 minutes once units are
rack mounted. |
Backup requirements |
None. |
System maintenance |
Treat as other server equipment. |
Management |
Monitoring |
Cache Adapter monitored on a 24 x 7 basis by
the SkyCache NOC. |
Reports |
Hit rate, miss rate, object size, bandwidth
savings. |
Interoperability |
Cache Turbocharging |
ICP-Compatible with- Cisco CacheEngine
version 1.7 Cobalt Systems CacheQube Entera TeraNode series. Inktomi Traffic Server 2.0
NLANR Squid 1.1, 1.2 Network Appliance NetCache 3.1, C230, C630 Rave Systems RM-AXi,
RM-AXmp |
News feed |
NNTP news feed. |
Support Availability |
24 x 7 service
Service level agreement
Internal escalation for problem resolution
|
Yes
Yes
Yes
|
Space Segment Satellite:
Band: |
GE-3, operated by GE Americom.
C/Ku-band |
Footprint |
United States, with spot beams to Alaska
and Hawaii.
Footprint Map |